C
IPMI Commands and Managed Sensors
146
258
(0x102)
FRU Thermal
Status
Temperature Threshold 0x1 State 0x1: Lower minor.
State 0x2: Lower major.
State 0x4: Lower critical.
State 0x8: Upper minor.
State 0x10: Upper major.
State 0x20: Upper critical.
Possible readings are encoded as a bit mask of 64 values:
0 Minor Temp Alarm
1 Major Temp Alarm
2Critical Temp Alarm
Table 19. Managed sensors for each FRU (continued)
# Name Type Category
Normal reading
or event state
Explanation of values
Table 20. Managed sensor for each shelf
# Name Type Category
Normal reading
or event state
Explanation of values
4198
(0x1066)
Shelf Fan Floor
Level
Cooling
Device
Sensor-
Specific
0x1E
(30%)
The current fan floor level in hex as a percentage of the maximum
fan speed.